Sump Pump Systems
Model 53 Cast Iron Series
- Non-Clogging vortex impeller.
- Float operated, submersible (NEMA 6) 2-pole mechanical switch & variable level long cycle systems available.
- UL Listed 3-wire cord plug; 9 ft. standard for automatic, 15 ft. standard for nonautomatic.
- Corrosion resistant powder coated epoxy finish.
- No sheet metal parts to rust or corrode.
- Stainless steel screws, switch arm, guard and handle.
- No screens to clog.
- Watertight neoprene ring between motor and pump housing.
- Solid buoyant polypropylene float.
- Motor - 60 Hz, 1550 RPM, oil-filled, hermetically sealed, automatic reset thermal overload protected.
- Upper and lower sleeve bearings running in bath of oil.
- Entire unit pressure tested after assembly.
- Carbon and ceramic shaft seal.
- Maximum temperature for effluent or dewatering - 130°F (54°C).
- Passes 1/2" inch spherical solids.
- 1 1/2" NPT Discharge.
- On point - 7 1/4";
- Off point - 3".
- Major width - 10 3/32".
- Height - 10 1/16".
- Cast iron switch case, motor & pump housing.
- Glass-filled polypropylene base.
- Engineered, glass-filled, plastic impeller with metal insert.
- Stainless steel guard & handle.
- Bearing - lower & upper oil fed cast iron.
Note: The sizing of effluent systems normally requires variable level float(s) controls and properly sized basins to achieve required pumping cycles or dosing timers with non-automatic pumps.
Model 98 Cast Iron Series
- Non-clogging engineered plastic vortex impeller design.
- Corrosion resistant powder coated epoxy finish.
- Durable cast construction. Cast switch case, motor, pump housing and base. No sheet metal parts to rust or corrode.
- Castings - All cast iron class 25-30 25000# tensile strength.
- Stainless steel screws, guard, handle, arm and seal assembly.
- Float operated submersible (NEMA 6) 2-pole mechanical switch.
- Motor - Permanent split capacitor, 60 Hz, 1725 RPM, oil-filled, thermetically sealed, automatic reset thermal overload protection.
- Bearings - Upper & lower oil fed cast iron.
- Carbon and ceramic shaft seal.
- Entire unit pressure tested after assembly.
- Watertight neoprene “” ring between motor and pump housing.
- Maximum temperature for effluent or dewatering 130°F - 54°C.
- Passes ½ inch spherical solids.
- No screens to clog.
- Standard cord length 15 ft. (UL Listed).
- 1½” NPT Discharge (1½” X 2” PVC Adapter included with BN & BE Models).
- On point - 9½”
- Off point - 3”
- Major width - 10 1/8”
- Height - 12”
Note: The sizing of effluent systems normally requires variable level float(s) controls and properly sized basins to achieve required pumping cycles or dosing timers with non-automatic pumps.